Arpit Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... RR 4035: Invalid number ERROR mahi indra asked Oct 26, 2010 | Replies (4) Hi ALL, Order of the ports... Please make sure that the order of the columns in the SELECT statement is same as the order of the ports. sql oracle share|improve this question asked Aug 27 '12 at 15:17 roymustang86 1,936113573 closed as not a real question by roymustang86, George Stocker♦ Aug 30 '12 at 1:11 It's difficult to navigate here

Regards, Devidas Kanchetti. mahi indra replied Oct 26, 2010 Hi, Please find the below sql query Thanks in advance. I am getting the following error while running workflow READER_1_1_1> RR_4035 SQL Error [ ORA-01722: invalid number and below is part of Log: READER_1_1_1> BLKR_16003 Initialization completed successfully. Arpit Shanker replied Oct 27, 2010 Hi Mahi, Please check whether the datatype of all the ports in the Source Qualifier matches the datatype in the database.

Ora 01722 Invalid Number Database Driver Error

You're now being signed in. Kindly refresh and validate your session and check the query order sync with the query used in the mapping level. Re: Ora-01722 : invalid number error in Informatica 9 Anil Borru Jun 3, 2014 3:35 AM (in response to user125563) Hi Punitha,As this error comes when you are trying to insert Legend Correct Answers - 4 points ProductsBig DataCloud IntegrationData IntegrationData QualityData SecurityInformatica PlatformIntegration Platform as a ServiceMaster Data ManagementSolutionsApplication Consolidation and MigrationCloud Integration and Data ManagementData GovernanceNext-Gen AnalyticsTotal Customer RelationshipIndustry SolutionsMarketplace

  1. And also in Source qualifier you can check by validating parts of the query.I see your query is doing only union's.
  2. No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers
  3. You can take help one of your team member to do the same.
  4. May be some of the fields datatype have changed .This is definetely datatypes issue.
  5. Answer: it is a property ...
  6. Improve Source Qualifier Performance problem with dates SQL query in Source qualifier ORA-01858: a non-numeric character was found where a numeric was expected in INFA Source Qualifier How to use sub
  7. Real Scenario 6: ORA-00001: unique constraint (XYZ...

ETL White Papers & Webcasts Buyer's Guide for Modern Project Teams The SMB of the Future: Start Fast, Then Accelerate Forrester Consulting Report: Empowered Customers Drive Collaborative Business Evolution Blog Articles Try just displaying the resulting strings without the TO_NUMBER call to see what you have. PLACE VARCHAR2(20); 4. Ora 01722 Invalid Number Error here is my Query: SELECT /*+INDEX(D DSD_CUST_IDX11)*/ a.to_cct_id, e.ic_ssk, b.month_rowid, b.sales_units, c.factor FROM (SELECT DISTINCT from_cct_id, to_cct_id,role_cd FROM staging.dsd_cust_affl a WHERE a.cct_interface_code = 'MEMB') a, staging.dsd_dsms_fact b, dsf_prod_factor c, staging.dsd_cust d,

There are probably data values from your SUBSTR expressions that are not returning numbers. The order of the ports in the select query is different from the order of the ports of the Source Qualifier. Top This thread has been closed due to inactivity. here All rights reserved.

Thanks, Rajiv Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Realtime Scenario 3:ORA-01401: inserted value too ... hari replied Sep 6, 2006 Yes, I have tried and the statement is working fine in Oracle. Function Name : Fetch SQL Stmt Join this group Popular White Paper On This Topic An Introduction to Big data and the CMO 4Replies Best Answer 0 Mark this reply as

Ora-01722 Invalid Number Database Driver Error... Function Name Fetch

Posted by anil kumar Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest Newer Post Older Post Home Subscribe to: Post Comments (Atom) Blog Archive ► 2014 (2) ► January (2) ▼ asked 4 years ago viewed 1392 times active 4 years ago Blog Stack Overflow Podcast #91 - Can You Stump Nick Craver? Ora 01722 Invalid Number Database Driver Error Recruiter wants me to take a loss upon hire What happens if one brings more than 10,000 USD with them into the US? Rr_4035 Sql Error Informatica Oracle selectUSER_ID,PINCODE from EXAMPLE; Note: Please select the ata for each column independently fromo Table data.(Press f4 on the table, you will get table description an then select data tab) 4->Once the

COMMENTS VARCHAR2(100); now when i execute the below query i got the below error. http://shpsoftware.com/invalid-number/invalid-number-error-in-sql.php Start a new thread here 1159135 Related Discussions ORA-01722: invalid number and getting empty buffer block for reading Error in Query at informatica level: RR_4035 : SQL Error [ ORA-01722: invalid Original answer by devidas kanchetti Jul 19, 2010 Contributors: Top Hi Kunal , As per the oracle corporation this is the reason... All product names are trademarks of their respective companies. Rr_4035 In Informatica

William Brooks replied Oct 26, 2010 I would have to see the SQL to be more certain, but these symptoms sound like you may be using passing a date as a This session was running fine earlier with the below query..Don't have any clue why it is throwing that error . Also I have checked all the data types but there are no issues. his comment is here PCMag Digital Group AdChoices unused Log In E-mail or User ID Password Keep me signed in Recover Password Create an Account Blogs Discussions CHOOSE A TOPIC Business Intelligence C Languages

Re: Ora-01722 : invalid number error in Informatica 9 Anil Borru Jun 3, 2014 3:35 AM (in response to user125563) Hi Punitha,As this error comes when you are trying to insert Help the community by fixing grammatical or spelling errors, summarizing or clarifying the solution, and adding supporting information or resources. But it is not working in Informatica.

Real Scenario 2: SQL Error [ [IBM][CLI Driver] SQ...

I got it. PINCODE NUMBER(6); 5. PCMag Digital Group AdChoices unused Log In E-mail or User ID Password Keep me signed in Recover Password Create an Account Blogs Discussions CHOOSE A TOPIC Business Intelligence C Languages anurag varshney replied Jan 23, 2008 Hi, what is the datatype of the e.family_grp_id ???

Please help.. Can anyone help, please? Reordered the SQL override columns in line with Ports in SQ. weblink Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters.

Thanks for your suggestions.. You're now being signed in. Ravi.......... Start a new thread here 1846237 Related Discussions Problem Running a workflow ORA-01007: variable not in select list RR_4035: Invalid number ERROR ORA-01722 Invalid Number Error in Informatica Debugging Process of

Wave Direct View All Topics View All Members View All Companies Toolbox for IT Topics Data Warehouse Groups Ask a New Question Informatica The Informatica group is your premier resource for So that it will gives you a wrong record which is Different from the Defined Datatype. 5-> Same repeat for the second column PINCODE. 6->From the above 2 steps(Step 4 and RealTime Scenario 8: ORA-01722: INVALID NUMBER Real time Scenario 7: MAX-CORE Value issue in Hash... if enable session wont fail but if the data is more than 28 digits than the Integration Service stores the result as a double value.regardsShirish Like Show 0 Likes (0)

Ora-01722 : invalid number error in Informatica 9 Gaurav Gupta Jun 3, 2014 7:11 AM (in response to user125563) Hi Punitha,the values that you are passing to the parameter is same another way is like we need to check the datatypes is in sequance or not. Thanks, Kuldeep Top This thread has been closed due to inactivity. Q: What is the Use of Update Transformation?

i need to migrate the code to Prod i checked the join condition every thing is fine... WRITER_1_*_1> WRT_8005 Writer run started.